Routen, Ashley, Upton, Dominic, Edwards, M.G. and Peters, D.M. ORCID: https://orcid.org/0000-0002-7873-7737 (2012) Intra‐ and Inter‐Instrument Reliability of the Actiwatch 4 Accelerometer in a Mechanical Laboratory Setting. Journal of Human Kinetics, 31. pp. 17-24. ISSN 1640-5544 (print version) 1899-7562 (electronic version)
PDF
2012_Journal_of_Human_Kinetics.pdf - Published Version Restricted to Repository staff only Download (297kB) | Request a copy |
Abstract
This study aimed to quantify the intra�]and inter�]instrument reliability of the Actiwatch 4 accelerometer
(AW4) in a mechanical setting. Twenty seven AW4 were attached to an isokinetic dynamometer and subjected to
angular acceleration for 30 min at 50 deg/sec representing moderate intensity (MPA condition) and 200 deg/sec
representing vigorous intensity (VPA condition), with a repeat trial conducted. Reliability was assessed using
coefficient of variation (CV), absolute percent error (APE), and intraclass correlation coefficients (ICC). Mean AW4
activity counts displayed acceptable reliability according to CV in both conditions (ConMPA: CVintra = 4.6%,
APEintra = 6.6%, CVinter = 6.4%, APEinter = 5.2%; ConVPA: CVintra = 3.9%, APEintra = 5.6%, CVinter = 5.9%,
APEinter = 4.7%). When counts were re�]categorised into minutes of MPA and VPA, lower CV values were observed
(ConMPA: CVintra = 3.2%, APEintra = 4.5%, CVinter = 4.3%, APEinter = 3.2%; ConVPA: CVintra = 0.0%,
APEintra = 0.0%, CVinter = 0.0%, APEinter = 0.0%). When activity counts were re�]categorised as minutes of MVPA,
excellent reliability was observed (CVintra, APEintra, CVinter, and APEinter = 0.0%) in both conditions. Mean AW4
activity counts exhibit reliability statistics comparable to other accelerometers. Reliability is improved when activity
counts are re�]categorised as time spent in MPA and VPA, with greatest reliability obtained when counts are recategorised
as time spent in MVPA. As MVPA is the subcomponent of physical activity most associated with health
benefits it would appear that the AW4 is reliable for measuring time spent in this health enhancing intensity category,at least from testing in a mechanical laboratory setting.
Item Type: | Article |
---|---|
Additional Information: | The electronic full-text for this article can be accessed via the Official URL. |
Uncontrolled Discrete Keywords: | physical activity, activity monitor, measurement, repeatability, accelerometer |
Subjects: | R Medicine > RC Internal medicine > RC1200 Sports Medicine |
Divisions: | College of Business, Psychology and Sport > School of Sport and Exercise Science |
Depositing User: | Ashley Routen |
Date Deposited: | 23 Mar 2012 09:52 |
Last Modified: | 08 Jun 2021 09:23 |
URI: | https://eprints.worc.ac.uk/id/eprint/1588 |
Actions (login required)
View Item |